SCANMATE A
DGH 6000
A UNIQUE ULTRA-PORTABLE A-SCAN
The innovative DGH 6000 A-Scan (Scanmate A) offers clinicians an unmatched level of usability and accuracy. Unique measurement guidance features assist in achieving optimal measurement values. These features allow the user to focus on application technique while the device’s software performs real-time waveform analysis and provides immediate feedback to the user.
The DGH Software supports multiple IOL formulas, including post-refractive formulas. A-Scan measurements can be taken via direct corneal contact or via water immersion method (Prager Shell® included).
INNOVATIVE IN MORE WAYS THAN ONE
A unique grading algorithm automatically ranks the probe’s alignment along the axis of measurement. Alignment ranking is immediate, with each qualified measurement assigned a 1-star, 2-star or 3-star rank (3-star representing best alignment). Aided by the audible feedback, the user can adjust the probe’s contact angle during a procedure, correcting misalignments and thereby optimizing measurement.
Unique compression lockout feature for use during contact measurements. When enabled, compression lockout will stop the system from measuring waveforms which show indications of corneal compression. Audible tones are provided to guide the user in adjusting contact pressure and aid in alleviating flattening of the cornea. The compression sensitivity level is adjustable to aid in obtaining contact measurements with minimum compression.
The DGH 6000 A-Scan can operate in either contact or immersion mode. Immersion mode eliminates corneal compression by allowing measurements in a water bath. The probe releases ultrasonic pulses into water (rather than directly to the eye). The pulses propagate through the water and into the tissue. This method of measurement eliminates potential deformation of the cornea’s geometry caused by direct contact from a probe.
The Scanmate software performs IOL calculations using modern predictive models, allowing the clinician to explore various treatment plans simultaneously.
The Scanmate software is offered as an unrestricted license, meaning it can be installed on multiple workstations to operate independently or as a networked system. Patient records are stored in a database that is easily searchable and can be backed-up using an in-program backup tool.
The Scanmate software offers a variety of report templates that summarize critical information. All reports are print and PDF-export ready. IOL Reports present comparative calculations for the selected lenses. Axial Length Progression Reports chart axial length changes over time.
MONITORING AXIAL LENGTH PROGRESSION
The DGH 6000 A-Scan is tailored to meet the needs of your myopia management program. In addition to providing consistent, accurate and reliable axial length measurements, the Axial Length Progression Report charts the axial length changes of each patient over a period of time.
Axial Length Progression Report
TOTAL SOFTWARE SOLUTION
The Scanmate Software combines the most advanced ultrasound technology available with the processing power, data storage and connectivity advantages of a personal computer. The DGH A-Scan software is capable of delivering customized Axial Length progression reports for your myopia management patients. Patient records are fully searchable and can be exported in a format that is compatible with EMR/EHR systems. The Scanmate software is designed to work on a Windows® computer. The DGH 6000 Scanmate A plugs into the USB 2.0 port of a Windows® computer that you may already have in your office or clinic*.
* See Specifications tab for minimum computer requirements.
Step 1: Patient Data : Populate the necessary fields and you’re ready to acquire measurements.
Step 2: Acquire measurements:Click on A-Scan modality icon, and start acquiring A-Scan data aided with audible feedback eliminating need for reacquiring data.
Step 3: IOL Calculations: Click on the IOL icon, enter required data and software will perform calculation.
Step 4: Reports: The Scanmate Software offers a variety of report templates that summarize critical information and are print and .PDF ready.
DGH 6000 Scanmate A Specifications |
|
A-Scan Probe Type | Internal, fixed single-element transducer. |
A-Scan Mode of Measurement | Contact or Immersion (using Prager Shell® immersion shell) |
Transducer Frequency | 10 MHz |
Axial Length Measurement Range | 15.00 mm – 40.00 mm |
ACD Measurement Range | 2.00 mm – 6.00 mm |
Lens Thickness Measurement Range | 2.00 mm – 7.50 mm |
Resolution | 0.01 mm |
Repeatability | ± 0.03 mm STDEV (Immersion) |
IOL Formulas | SRK II, Binkhorst, SRK/T, Holladay 1, Hoffer Q, Haigis |
IOL Formulas (Post Refractive) | Double K (SRK/T), History Derived, Clinically Derived (Shammas), Refraction Derived, Contact Lens Over-Refraction |
Eye Types | Aphakic, Normal, Cataract, Dense Cataract, Pseudophakic (Silicone/PMMA, Acrylic), Normal / Silicone Oil Vitreous |
Unit Dimensions |
|
Dimensions | 5.73” (145.54 mm) L X 3.45” (87.63 mm) W X 1.50” (38.1 mm) H |
Weight | 2 lbs (Complete Kit), <1 lbs (Unit Only) |
Probe Dimensions | 2.75“ (69.85 mm) Long X 0.25” (6.35 mm) Diameter |
Connection Type | USB (Micro USB to USB 2.0 or higher) |
Software Features |
|
Measurements Features | Audible Feedback for Probe Alignment, Corneal Compression detection, fully configurable velocities, save video and individual A-Scan measurements, Automatic and Manual measurements modes |
Report Features | Single Page IOL Calculations report, A-Scan measurement review page, Customizable Report Options, Print to Local or Network Printer, Axial Length Progression Report (Myopia Management), export as .pdf. |
Software Application Requirements |
|
Hardware Requirements | Intel i3 or higher at 2.0+ GHz, 4GB RAM or higher, 128 GB SSD/HDD or higher
2 x 2.0 USB, 1280 x 800 display resolution or higher |
Operating System Requirements | Windows 10 or higher (64 bit)
MS Server 2016 or higher (64 bit) |
BROCHURE
OPERATOR'S MANUAL
DGH Technology, Inc.
110 Summit Drive, Suite B
Exton, PA 19341
Phone: (610) 594-9100
Fax: (610) 594-0390
Toll Free: (800) 722-3883
info@dghtechnology.com
SALES:
Eastern U.S.
Contact: Russell Schlage
(727) 692-8327
russell@dghtechnology.com
Western U.S.
Contact: Rafael Ramirez
(619) 993-4608
rafael@dghtechnology.com
International
Contact: Niket Dave
(312) 918 9808
nick@dghtechnology.com
Headquarters
Contact: Darrell Glasgow
(800) 722-3883
sales@dghtechnology.com
DGH DIRECT PURCHASE OPTION
Purchasing DGH products directly from DGH is the only way to ensure that you are purchasing the appropriate products for your practice at the best price possible. Simply contact DGH to arrange a personal consultation with our experienced Sales and Service Representatives who have the technical expertise required to determine which DGH products are best suited to your practice, and they will also discuss how the benefits of the Direct Purchase Option maximize the total value of your purchase.
BENEFITS OF THE DGH DIRECT PURCHASE OPTION
- Our Sales and Service Representatives are your personal DGH liaisons for all your pre-sales and post-sales needs.
- Special discount pricing for qualified buyers on all DGH products.
- On-line demonstrations.
- Customer Satisfaction Guarantee: Return any purchase within the first 30 days for a full refund.
- Discounted pricing for a new DGH product when trading in a used DGH product.
- Special extended warranty offers.
- Priority Customer Service.
- Customized financial options available through DGH affiliates.
Note: The DGH Direct Purchase Option is available only for customers based in the USA.